CBRN / NBC Filtration Systems for Shelters, Bunkers & Protected Facilities
Atmas Group offers a wide range of standard and customizable CBRN (chemical, biological, radiological and nuclear) air filtration and emergency ventilation systems, also referred to as NBC systems. They are designed for civil defence shelters, safe rooms, bunkers, containerized shelters and other protected facilities.
The systems filter incoming outside air and help maintain positive air pressure inside the protected space, reducing the risk of contaminated air entering through gaps or leaks. Atmas can tailor the system configuration to the required airflow, occupancy, available installation space and project-specific protection requirements.

SAFE 360 - CBRN / NBC Filtration System
SAFE 360 is a modern, cost-effective CBRN / NBC filtration system and emergency ventilation system for residential shelters, small bunkers and safe rooms.
Main specifications:
Airflow filtration: 36 m3/h
Airflow ventilation: 54 m3/h
Electrical Requirements: 1-phase, 100-230V AC / 12V DC (optional)
Manual backup: included
Installation variants: floor-free (wall)

ARC 50 - CBRN / NBC Filtration System
ARC 50 is a modern, compact CBRN / NBC filtration system and emergency ventilation system for shelters, bunkers and protected facilities.
Main specifications:
Airflow filtration: 50 m3/h
Airflow ventilation: 100 m3/h
Electrical Requirements: 1-phase, 100-230VAC / 115 VAC (optional)
Manual backup: included
Installation variants: floor-free (wall)

ARC 100 - CBRN / NBC Filtration System. NEW! PRE-ORDER
ARC 100 is a modern, compact CBRN / NBC filtration system and emergency ventilation system for shelters, bunkers and protected facilities.
Main specifications:
Airflow filtration: 100 m3/h
Airflow ventilation: 200 m3/h
Electrical Requirements: 1-phase, 100-230VAC / 115 VAC (optional)
Manual backup: included
Installation variants: floor-free (wall)

ARC 180 - CBRN / NBC Filtration System
ARC 180 is a modern CBRN / NBC filtration system and emergency ventilation system for shelters, bunkers and protected facilities.
Main specifications:
Airflow filtration: 180 m3/h
Airflow ventilation: 360 m3/h
Electrical Requirements: 1-phase, 100-230VAC / 115 VAC (optional)
Manual backup: included
Installation variants: floor mounted / wall mounted (floor-free)

ARC 240 - CBRN / NBC Filtration System
ARC 240 is a modern CBRN / NBC filtration system and emergency ventilation system for shelters, bunkers and protected facilities.
Main specifications:
Airflow filtration: 240 m3/h
Airflow ventilation: 480 m3/h
Electrical Requirements: 1-phase, 100-230VAC / 115 VAC (optional)
Manual backup: included
Installation variants: floor mounted / wall mounted (floor-free)

ARC 300 - CBRN / NBC Filtration System
ARC 300 is a modern CBRN / NBC filtration system and emergency ventilation system for shelters, bunkers and protected facilities.
Main specifications:
Airflow filtration: 300 m3/h
Airflow ventilation: 600 m3/h
Electrical Requirements: 1-phase, 100-230VAC / 115 VAC (optional)
Manual backup: included
Installation variants: floor mounted / wall mounted (floor-free)

ARC 450 - CBRN / NBC Filtration System
ARC 450 is a modern CBRN / NBC filtration system and emergency ventilation system for shelters, bunkers and protected facilities.
Main specifications:
Airflow filtration: 450 m3/h
Airflow ventilation: 900 m3/h
Electrical Requirements: 1-phase, 100-230VAC / 115 VAC (optional)
Manual backup: included
Installation variants: floor mounted / wall mounted (floor-free)

ARC 600 - CBRN / NBC Filtration System
ARC 600 is a modern CBRN / NBC filtration system and emergency ventilation system for shelters, bunkers and protected facilities.
Main specifications:
Airflow filtration: 600 m3/h
Airflow ventilation: 1200 m3/h
Electrical Requirements: 1-phase, 100-230VAC / 115 VAC (optional)
Manual backup: included
Installation variants: floor mounted / wall mounted (floor-free)

ARC 900 - CBRN / NBC Filtration System
ARC 900 is a modern CBRN / NBC filtration system and emergency ventilation system for shelters, bunkers and protected facilities.
Main specifications:
Airflow filtration: 900 m3/h
Airflow ventilation: 1800 m3/h
Electrical Requirements: 3-phase 400V / 240V AC (optional)
Manual backup: No
Installation variants: floor mounted

ARC 1200 - CBRN / NBC Filtration System
ARC 1200 is a modern CBRN / NBC filtration system and emergency ventilation system for shelters, bunkers and protected facilities.
Main specifications:
Airflow filtration: 1200 m3/h
Airflow ventilation: 2400 m3/h
Electrical Requirements: 3-phase 400V / 240V AC (optional)
Manual backup: No
Installation variants: floor mounted

ARC 1800 - CBRN / NBC Filtration System
ARC 1800 is a modern CBRN / NBC filtration system and emergency ventilation system for shelters, bunkers and protected facilities.
Main specifications:
Airflow filtration: 1800 m3/h
Airflow ventilation: 3600 m3/h
Electrical Requirements: 3-phase 400V / 240V AC (optional)
Manual backup: No
Installation variants: floor mounted

IVL-1 - CBRN / NBC Filtration System
ARC IVL-1 is a modern CBRN / NBC filtration system and emergency ventilation system for shelters, bunkers and protected facilities design to meet Finnish shelter regulation requernments.
Main specifications:
Airflow filtration: 150 m3/h
Airflow ventilation: 600 m3/h
Electrical Requirements: 3-phase 400V
Manual backup: Yes
Installation variants: wall mounted

CBRN / NBC Filtration Batteries
CBRN / NBC filters batteries (filter banks) systems are scalable units for large or special requernment shelters and bunkers with airflow up to 18,000 m3/h per one unit.
Main specifications:
Airflow Filtration: up to 18,000 m3/h per line (several lines can be connected)
Numer of filters per line: up to 10
Filer which can be used: 600 / 900 / 1200 / 1800 m3/h
Electrical Requirements: acording to design
Manual backup: according to design
Installation variants: according to design
* The shelter air volume and air change per hour (ACH) calculated according to one complete ACH. In some standards minimum two ACH is required.
In selection of the systems beside the parameter of air changes, other parameters should be taken into account like number of people in the shelter, national or local standard for air volume per person, additional components of the shelter like airlocks, generator rooms, air distribution and leakage.
We recommend to contact us for support in selecting the correct system for a specific shelter.
Explore Atmas Range of CBRN / NBC filtration and emergency ventilation systems
Unlike most products that degrade with use over time, a CBRN air filtration system is expected to remain on standby for years—possibly decades—without being used, and yet perform flawlessly the moment it's needed. Whether facing nuclear fallout, chemical agents, biological contaminants, wildfire smoke, or industrial toxins, the system must deliver clean, safe air into a sealed environment with zero margin for failure.
This unique requirement demands careful evaluation of both the manufacturer and the system’s specifications to ensure reliability under extreme conditions.
Why Choose Our CBRN Filtration Systems?
You get systems from a trusted global leader in CBRN filtration, which produces over 10,000 systems and filters annually. Subject to frequent quality and procedural audits by governments and third parties, the products are certified and recertified yearly, undergoing rigorous performance testing. With systems ranging from 36 m³/h to over 1,800 m³/h and fully custom setups for larger airflow requirements, we offer tailored solutions for any shelter size.
General Points for Selecting the CBRN / NBC Filtration System

Step 1: Determine Your Required Airflow
1. Airflow per Person
Estimate the total airflow by multiplying the number of occupants by the airflow needed per person. Common standards recommend 3–6 m³/h per person, with 6 m³/h per person preferred for civil defense or private shelters, especially in warm climates. Military shelters may require up to 17 m³/h per person, due to higher activity levels.
Example: 50 persons × 6 m³/h = 300 m³/h
2. Air Changes per Hour (ACH)
ACH reflects how many times the air inside the shelter is completely replaced each hour. Multiply the shelter’s internal volume by the desired ACH. For private use, 2–6 ACH is recommended, with 1 ACH considered a minimum.
Example: Shelter volume: 200 m³ × 2 ACH = 400 m³/h
3. Leakage and Exhaust Compensation
To maintain positive pressure (typically 100–250 Pa)—which prevents contaminants from entering the shelter—you must account for leaks and exhaust airflow (e.g., through toilets, kitchens, airlocks). It's advisable to pressure-test the shelter pre-installation. If this data isn't available, include a 25% safety margin.
Example: Measured leakage + exhaust = 440 m³/h Add 25% margin = 550 m³/h
4. Airlocks or other filtered fresh air consumers
Adding an airlock in the shelter usually require additional amount of fresh filtered air as in some cases more 50 air changes per hour may be required to "flush" the airlock from contaminated air.
Additional consumers of fresh air may be generators if installed inside the toxic free area and other equipment that require air or oxygen.
Step 2: Select the System
From the three calculations above, take the highest value—in this case, 550 m³/h—and select the next available system size that meets or exceeds it. For example, the Arconik ARC600, rated at 600 m³/h, would be appropriate.
Always opt for a buffer above your minimum requirements. Over time, aging seals, structural shifts, or external damage may increase leakage, especially after explosive events or long periods of disuse. Built-in redundancy is essential. A manual crank backup is critical to ensure functionality during power outages.
Contact Form
Why We Collect Your Contact Information
We use your contact information to respond to your inquiry and provide the requested information, products, services, or support.
Where appropriate, your inquiry and contact details may be shared with an authorized Atmas Group distributor, partner, or representative responsible for your country, region, or project. We do not sell your personal data.
By submitting this form, you acknowledge that Atmas Group Oy will process your personal data as described in our Privacy Policy, including information about data sharing, storage, protection, and your privacy rights.