The reinforcement of existing facilities and internal spaces against blast effects is an important consideration in the development of protective environments. Buildings and rooms may require additional protection against several types of threats, including blast effects, ballistic impacts, fragments and forced entry.
Atmas Group provides shelter reinforcement systems designed for both retrofit projects and new construction. These systems are intended to upgrade the protection level of rooms and structures through the integration of reinforced walls, ceiling protection, blast-proof doors, window covers and other composite components.
The solutions can be adapted to different project requirements and supplied as modular structures or ready-for-installation kits.
Product and solution page:https://atmasgroup.com/solutions/facilities-protection/blast-reinforcement
1. Scope of Facility Reinforcement Systems
Facility reinforcement involves upgrading the protective characteristics of an existing room or incorporating protective components into a new structure.
According to the Atmas Group product information, the systems can include:
Wall protection systems.
Ceiling protection systems.
Blast-proof doors.
Blast and ballistic window covers.
Other specially designed composite components.
The purpose of integrating these elements is to improve the protection of internal spaces against blast, ballistic and forced-entry threats.
The systems are intended for both new projects and the modernization of existing facilities. This makes retrofit installation an important part of the solution.
2. Protection Against Blast Effects
Blast protection is one of the principal functions identified for these reinforcement systems.
The product information states that the systems have been live-tested and can withstand high blast loads. It also reports live testing in a real-case event involving rocket attacks.
The protective configuration may incorporate reinforced walls, ceiling components, blast-proof doors and window covers. These elements form part of the overall reinforcement approach for the room or facility.
The source does not specify a numerical blast-pressure rating. Therefore, the applicable pressure resistance should be confirmed for the particular project and selected configuration.
3. Optional Ballistic and Fragment Protection
The reinforcement systems can also include optional protection against ballistic threats and fragments.
According to the product information, this protection has been live-tested, with optional additional upgrades available to achieve higher protection levels.
The exact configuration depends on the selected project requirements. The available information does not provide specific ballistic classifications, projectile types or numerical resistance values.
For this reason, the required protection level should be defined and confirmed during project specification.
4. Forced-Entry Resistance
Forced-entry resistance is another protection capability identified by Atmas Group.
The systems can be upgraded to FE-60.
This capability is relevant when a protected space must address not only external blast and ballistic threats but also attempts at forced access.
The source does not provide further details about the testing procedure or the exact test criteria associated with FE-60. These details should be requested from the supplier when preparing a project specification.
5. Additional Reinforcement Against Earthquake Effects
The product information also identifies additional reinforcement against destructive earthquake effects.
This means that the system can be considered for projects where reinforcement against more than one type of threat is required.
No seismic performance rating, acceleration value or structural design parameter is specified on the referenced page. Such values should not be assumed and must be established for the individual project.
6. Retrofit Installation and Modular Construction
One of the stated advantages of the Atmas Group solution is its suitability for fast installation.
The reinforcement system has a modular structure that can be adapted to a project and supplied as a ready-for-installation kit.
This approach is relevant to both new construction and existing facilities requiring protective upgrades.
The product information also identifies a special blast-proof door design that opens inward. This configuration is described as making retrofit installation in existing structures easier.
The modular approach allows the reinforcement components to be considered as part of a coordinated project rather than as unrelated individual elements.
7. Integration with Doors, Windows and Other Shelter Components
Facility reinforcement is not limited to wall and ceiling protection.
The system can be integrated with:
Blast-proof doors.
Blast and ballistic window covers.
Other shelter components.
This integration allows the selected protective elements to be incorporated into the overall room or facility configuration.
The product information specifically identifies compatibility with other shelter components as one of the system's advantages.
8. Architectural Appearance and Internal Environment
Another stated product advantage is the possibility of covering the reinforcement system to provide the visual appearance of a standard room.
This option may be relevant in facilities where the protected space is also intended to retain an ordinary interior appearance.
The source does not specify particular finishing materials, colours or architectural configurations. These details should therefore be agreed as part of the project design.
9. Main Product Advantages
Atmas Group identifies the following advantages:
Feature | Description |
Live testing | Tested in a real-case event involving rocket attacks |
Blast protection | Designed to withstand high blast loads |
Optional ballistic protection | Additional protection against ballistic threats and fragments |
Forced-entry upgrade | Can be upgraded up to FE-60 |
Earthquake reinforcement | Additional reinforcement against destructive earthquake effects |
Installation | Fast installation |
Modular structure | Adapted to the project and available as a ready-for-installation kit |
Appearance | Can be covered to resemble a standard room |
Integration | Can be integrated with blast-proof doors, windows and other shelter components |
Cost | Described by the manufacturer as cost-effective compared with alternatives |
10. Project Planning and Specification
The selection of a reinforcement configuration should be based on the requirements of the individual facility.
The project should identify which protection capabilities are required, including blast protection, optional ballistic and fragment protection, forced-entry resistance and additional earthquake reinforcement.
The scope of the installation should also establish which components are required: walls, ceilings, doors, window covers and other composite elements.
For retrofit projects, the existing structure and the intended installation arrangement should be considered when defining the configuration.
The manufacturer should confirm the applicable technical parameters, testing documentation, protection levels and installation requirements for the selected project. The referenced product information does not provide numerical blast ratings, ballistic classifications or detailed seismic specifications.
Conclusion
Reinforcement of facilities and internal spaces against blast effects requires a coordinated approach to protective construction. Atmas Group describes a modular system intended for new projects and retrofit applications, combining wall and ceiling protection with blast-proof doors, window covers and other composite components.
The stated capabilities include blast protection, optional ballistic and fragment protection, forced-entry upgrades up to FE-60 and additional reinforcement against earthquake effects. Fast installation, project-adapted modular construction, the option to cover the system with a standard-room appearance and integration with other shelter components are also identified as product advantages.