BVNO - Blast Valve

Overview

Blast valves are normally open valves which allow movement of air in regular operation and provide automatic closing action in case of incoming blast wave. The valves are designed for installation on ventilation openings or as part of the duct for protection of ventilation ways and internal spaces against destructive blast wave effects.

  • BVNO series of blast valves was developed by Arconik for use in civil defence shelters, bunkers, safe rooms and other protected spaces.​

  • BVNO are automatic double action valves designed to protect from positive and negative phases of the blast.

  • The valves are extremely durable and can withstand a wide range of temperatures and resistant to corrosion.

  • Simple Installation in new structures with pre-installed wall sleeves or retrofit flanges.

  • The valves can be equipped with pre-filter for removing dust particles, special case with flanges or connectors to the duct.

  • Tested and certified to SI 4570 standard and/or compatible with requiernments of other shelter norms

  • Approved by civil defence authorities in different countries

  • Tens of thousands of company's products are installed in protected spaces

BVNO 50.jpg

BVNO 50 - Blast Valve 

  • Practical pressure durability: >900 (9) kPa (bar)

  • Nominal airflow: ~ 50 m3/h

  • Pressure drop @ nominal: 200 Pa

  • Mechanical shock resistance: >12 g

  • Connection to wall: flange 4 Inch

Configuration
  • 4Y - valve only

  • 4X - valve with pre-filter

Downloads

Ask us for DWG models or other design files

BVNO 550 600 1000 web3.jpg

BVNO 550 - Blast Valve 

  • Maximum pressure durability: >2000 (20) kPa (bar)

  • Practical pressure durability: >900 (9) kPa (bar)

  • Nominal airflow: ~ 550 m3/h

  • Pressure drop @ nominal: 200 Pa

  • Mechanical shock resistance: >12 g

  • Connection to wall: flange 8 Inch

Configuration
  • 8Y - valve only

  • 8YZ - valve only with flange exit

  • 8X - valve with pre-filter

  • 8L - with pre-filter, 90 deg exit

  • 8Z - with pre-filter, inline exit

Downloads

Ask us for DWG models or other design files

BVNO 550 600 1000 web3.jpg

BVNO 600 - Blast Valve 

  • Maximum pressure durability: >2000 (20) kPa (bar)

  • Practical pressure durability: >900 (9) kPa (bar)

  • Nominal airflow: ~ 600 m3/h

  • Pressure drop @ nominal: 200 Pa

  • Mechanical shock resistance: >12 g

  • Connection to wall: flange 8 Inch

Configuration
  • 8Y - valve only

  • 8YZ - valve only with flange exit

  • 8X - valve with pre-filter

  • 8L - with pre-filter, 90 deg exit

  • 8Z - with pre-filter, inline exit

Downloads

Ask us for DWG models or other design files

BVNO 550 600 1000 web3.jpg

BVNO 1000 - Blast Valve 

  • Maximum pressure durability: >2000 (20) kPa (bar)

  • Practical pressure durability: >900 (9) kPa (bar)

  • Nominal airflow: ~ 1000 m3/h

  • Pressure drop @ nominal: 200 Pa

  • Mechanical shock resistance: >12 g

  • Connection to wall: flange 8 Inch

Configuration
  • 8Y - valve only

  • 8YZ - valve only with flange exit

  • 8X - valve with pre-filter

  • 8L - with pre-filter, 90 deg exit

  • 8Z - with pre-filter, inline exit

Downloads

Ask us for DWG models or other design files

BVNO 1800 2600.jpg

BVNO 1800 - Blast Valve 

  • Maximum pressure durability: >2000 (20) kPa (bar)

  • Practical pressure durability: >900 (9) kPa (bar)

  • Nominal airflow: ~ 1800 m3/h

  • Pressure drop @ nominal: 200 Pa

  • Mechanical shock resistance: >12 g

  • Connection to wall: flange 8 Inch

Configuration
  • 8Y - valve only

  • 8YZ - valve only with flange exit

  • 8X - valve with pre-filter

  • 8L - with pre-filter, 90 deg exit

  • 8Z - with pre-filter, inline exit

Downloads

Ask us for DWG models or other design files

BVNO 1800 2600.jpg

BVNO 2600 - Blast Valve 

  • Maximum pressure durability: >2000 (20) kPa (bar)

  • Practical pressure durability: >900 (9) kPa (bar)

  • Nominal airflow: ~ 2600 m3/h

  • Pressure drop @ nominal: 200 Pa

  • Mechanical shock resistance: >12 g

  • Connection to wall: flange 8 Inch

Configuration
  • 8Y - valve only

  • 8YZ - valve only with flange exit

  • 8X - valve with pre-filter

  • 8L - with pre-filter, 90 deg exit

  • 8Z - with pre-filter, inline exit

Downloads

Ask us for DWG models or other design files

BVNO 2900 web2.jpg

BVNO 2900 - Blast Valve 

  • Maximum pressure durability: >2000 (20) kPa (bar)

  • Practical pressure durability: >900 (9) kPa (bar)

  • Nominal airflow: ~ 2900 m3/h

  • Pressure drop @ nominal: 200 Pa

  • Mechanical shock resistance: >12 g

  • Connection to wall: flange 14 Inch

Configuration
  • 14Y - valve only

  • 14YZ - valve only with flange exit

  • 14X - valve with pre-filter

  • 14L - with pre-filter, 90 deg exit

  • 14Z - with pre-filter, inline exit