ARC Series

A line of CBRN Filtration & Ventilation Systems for Civil Defence Shelters, Bunkers and Protected Spaces.
ARC series includes the following systems: ARC 100, ARC 180, ARC 240, ARC 300, ARC 450, ARC 600, ARC 900, ARC 1200 & ARC 1800.

ARC series systems are advanced, professional and certified collective protection CBRN (chemical, biological, radiological and nuclear) air filtration and ventilation systems designed for installation in protected spaces like shelters, bunkers, strategic facilities and other applications for providing fresh filtered air for safe breathing, maintaining of overpressure and creation of protected environment in the intended area.

  • All components of ARC systems are tested and certified according to SI 4570 and approved for use by national authorities

  • Installed in shelters worldwide

ARC Systems Highlights

Advanced Emergency Ventilation and Air Filtration Systems for Collective Protection and Safe Environment

Key Features:

  • The ARC series was developed by Arconik for use in residential shelters, small bunkers, safe rooms and other protected spaces.​

  • The systems are tested, and all their components are certified for compliance with technical requirements of SI 4570 standard (Air ventilation and filtration systems for shelter and protected spaces).

  • The systems were approved for use by Civil Defence Command and installed in tens of thousands of shelters around the world.

  • Standard ARC system kit includes – blast valve, prefilter, electric blower, manual backup (optional), CBRN filter, air duct and hoses, noise silencer, overpressure valve/s.

  • The ARC systems models ARC 100, ARC 180, ARC 240, ARC 300, ARC 450 and ARC 600 have versions for floor and wall installations (what allows efficiently to maximize the floor space).

  • Simple Installation in new structures with pre-installed (cast in concrete) wall sleeves with 8-inch flanges or retrofit installation on existing walls with retrofit 8-inch flanges connected to the wall with concrete anchors.

  • Ready for use withing minutes and can be operated by one person.

  • The electric blower fan can be operated with 230 or 115 VAC. Additionally a manual backup device is available in versions up to 600 m3/h airflow for insuring continued operation of the system also in case of electric outage.

Applications:

Ideal for civil defence shelters, government bunkers, emergency shelters, and critical infrastructure requiring high-security air filtration and overpressure maintenance.

ARC Type Systems Main Components

  1. CBRN filter (combined filter carbon + HEPA)

  2. Electric Blower

  3. Manual backup (optional for systems up to ARC 600)

  4. Blast valve with prefilter

  5. Silencer + airflow indicator

  6. Airflow control damper

  7. Overpressure blast valve/s

Standard Line of ARC Systems

ARC CBRN filtration systems includes a wide line of systems for small, medium and large size shelters and protected facilities which can include manual backup or designed to work with generator backup.  

The shelter air volume and air change per hour (ACH) calculated according to one complete ACH. In some standards minimum two ACH is requered.

ARC 100

Recommended max. shelter air volume up to 100 m3*
  • Nominal airflow in filtration mode: 100 m3/h (CMH)

  • Nominal airflow in ventilation mode: 200 m3/h (CMH)

  • Electrical requirements: 230V AC (one phase) / 115 V AC (optional)

  • Manual backup: included

  • Variants: floor installation or floor-free (wall/hidden) installation

ARC 180

Recommended max. shelter air volume up to 180 m3*
  • Nominal airflow in filtration mode: 180 m3/h (CMH)

  • Nominal airflow in ventilation mode: 360 m3/h (CMH)

  • Electrical requirements: 230V AC (one phase) / 115 V AC (optional)

  • Manual backup: included

  • Variants: floor installation or floor-free (wall/hidden) installation

ARC 240

Recommended max. shelter air volume up to 240 m3*
  • Nominal airflow in filtration mode: 240 m3/h (CMH)

  • Nominal airflow in ventilation mode: 480 m3/h (CMH)

  • Electrical requirements: 230V AC (one phase) / 115 V AC (optional)

  • Manual backup: included

  • Variants: floor installation or floor-free (wall/hidden) installation

ARC 300

Recommended max. shelter air volume up to 300 m3*
  • Nominal airflow in filtration mode: 300 m3/h (CMH)

  • Nominal airflow in ventilation mode: 600 m3/h (CMH)

  • Electrical requirements: 230V AC (one phase) / 115 V AC (optional)

  • Manual backup: included

  • Variants: floor installation or floor-free (wall/hidden) installation

ARC 450

Recommended max. shelter air volume up to 450 m3*
  • Nominal airflow in filtration mode: 450 m3/h (CMH)

  • Nominal airflow in ventilation mode: 900 m3/h (CMH)

  • Electrical requirements: 230V AC (one phase) / 115 V AC (optional)

  • Manual backup: included

  • Variants: floor installation or floor-free (wall/hidden) installation

ARC 600

Recommended max. shelter air volume up to 600 m3*
  • Nominal airflow in filtration mode: 600 m3/h (CMH)

  • Nominal airflow in ventilation mode: 1200 m3/h (CMH)

  • Electrical requirements: 230V AC (one phase) / 115 V AC (optional)

  • Manual backup: not included (optional operation from generator)

  • Variants: floor installation

ARC 900

Recommended max. shelter air volume up to 900 m3*
  • Nominal airflow in filtration mode: 900 m3/h (CMH)

  • Nominal airflow in ventilation mode: 1800 m3/h (CMH)

  • Electrical requirements: 400V AC (three phase)

  • Manual backup: not included (optional operation from generator)

  • Variants: floor installation

ARC 1200

Recommended max. shelter air volume up to 1200 m3*
  • Nominal airflow in filtration mode: 1200 m3/h (CMH)

  • Nominal airflow in ventilation mode: 2400 m3/h (CMH)

  • Electrical requirements: 400V AC (three phase)

  • Manual backup: not included (optional operation from generator)

  • Variants: floor installation

ARC 1800

Recommended max. shelter air volume up to 1800 m3*
  • Nominal airflow in filtration mode: 1800 m3/h (CMH)

  • Nominal airflow in ventilation mode: 3600 m3/h (CMH)

  • Electrical requirements: 400V AC (three phase)

  • Manual backup: not included (optional operation from generator)

  • Variants: floor installation

*The shelter air volume and air change per hour (ACH) calculated according to one complete ACH. In some standards minimum two ACH is required.

In selection of the systems beside the parameter of air changes, other parameters should be taken into account like number of people in the shelter, national or local standard for air volume per person, additional components of the shelter like airlocks, generator rooms, air distribution and leakage.

We recommend to contact us for support in selecting the correct system for a specific shelter.

ARC Installation Options

Floor Installed Versions

​Available for the following ARC systems:​ ARC 100, ARC 180, ARC 240, ARC 300​, ARC 450, ARC 600, ARC 900, ARC 1200, ARC 1800

Floor-free (Wall) Installed Versions

​Available for the following ARC systems:​ ARC 100, ARC 180, ARC 240, ARC 300​, ARC 450, ARC 600

Preparation for Installation

Definitions:

  • Air inlet – ventilation opening in the shelter perimeter wall intended for pulling fresh air from outside.

  • Air outlet – ventilation opening in the shelter perimeter wall intended for releasing air from the shelter. Blast valve – a protective device designed for installation on/in the air inlet for protecting the internal space and the system components from blast wave pressure.

  • Overpressure valve – a protective device designed for installation on/in the air outlet for controlled release of air from the shelter and maintenance of overpressure levels in the protected space.

  • Flange – devices for connection of air duct or valves.

Prior installation it is recommended to perform a pressure/gas tightness test to identify and treat the air leakage sources from the shelter perimeter. For proper operation of the system and creation of overpressure (positive differential pressure) inside, the shelter has to be airtight.
 

Overpressure helps to prevent penetration of contamination through small cracks or opening in the shelter perimeter.

Wall Sleeve with Flange

Wall sleeves are hollow pipes which are intended to be casted in shelter concrete walls for allowing passage of air from outside and inside. Wall sleeves are usually connected with flanges on the shelter side to allow simple connection of the blast valve, overpressure valve, gas tight valve, air duct, cable gas tight passages and more.​​

* wall sleeves are not included in the SAFE 360 kit and can be purchased separately.

Retrofit Flange​

Retrofit flanges designed to allow connection of the blast valves and overpressure valves to existing walls in the perimeter of the shelter/ protected space. The flanges connected to the wall by special concrete anchors and have pre installed bolts for securing the valves with nuts.

* retrofit flanges are not included in the SAFE 360 kit and can be purchased separately.